Brocade Fibre Channel Switch ’sfpshow‘ – will print stats pertaining to a particular port on the switch

This example shows zero voltage and an output power of -17dBm in this situation the SFP itself is faulty

switch01> sfpshow 8
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 540c404000000000 200,400,800_MB/s M5,M6 sw Short_dist
Encoding: 1 8B10B
Baud Rate: 85 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u: 5 (units 10 meters)
Length 62.5u:2 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000012-01
Vendor Rev: A
Wavelength: 850 (units nm)
Options: 003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: UAF1093100007HE
Date Code: 090728
Temperature: 38 Centigrade
Current: 0.000 mAmps
Voltage: 3303.9 mVolts
RX Power: -2.1 dBm (623.5 uWatts)
TX Power: -17.2 dBm (19.2 uWatts)